Sensor Amplification Device
Amplifier is controlled by a µ-processor. Employs an 11-pin circular plug for easy connection. Features an NPN output & Alarm output. This device is able to perform self-diagnostic functions.
Specifications:
- 230: 195 To 265 VAC, 45 To 65 Hz
- Rated Operational Voltage (UB) Pins 2 & 10
- 115: 98 To 132 VAC, 45 To 65 Hz
- 024: 20.4 To 27.6 VAC, 45 To 65 Hz
- 924: 20.4 To 27.6 VAC/DC Class 2
- Delay On Operate (Tv): < 300 Ms
Rated Operational Power:
- AC Supply: 3.3 VA
- AC/DC Supply: 1.6 VA / 1.4 W
Outputs:
- Relay Rating (Agcdo): µ (Micro Gap)
- Resistive Loads
- AC1: 8 A / 250 VAC (2500 VA)
- DC1: 0.2 A / 250 VDC (50 W) or 2 A 25 VDC (50 W)
- Electrical Life (Typical) AC1: > 100.000 Operations
Transistor Output Data
- Output Current (Ie) < 100 Ma @ 10-40 VDC
- (Max. Load Capacity 100 Nf)
- Voltage Drop (Ud) < 2,5 VDC @ 100 Ma
Output Function: Make Or Break On DIP-Switch
- Relay: SPDT
- Transistor: NPN / PNP, 100 Ma, 10-40 VDC
- Alarm: NPN / PNP, 100 Ma, 10-40 VDC
- Delay On Alarm: 10 Sec
Test Input (Mute) NPN PNP
- Emitter Enabled: > 5.0 VDC < VCC - 3 VDC
- Emitter Disabled: < 3.0 VDC > VCC - 5 VDC
- Imax @ 40 VDC: 1 Ma
Protection Output
- Transistor: Reverse Polarity, Short Circuit And Transients
Supply To Sensors
- Emitter: Pins 5 & 7
- Supply Voltage (Open Loop): 15 V Square Wave
- Current: < 450 Ma, Short Circuit Protected
- Supply Voltage (Open Loop) 5 VDC
- Short-Circuit Current 10 Ma
- Input Resistance 470 _
Emitter Power
- Power: Settings On DIP Switch No 4, 50 % Or 100 % Range
- Sensitivity Adjustment
- Manual: 240° Potentiometer
- Automatic /Auto LED ON): Potentiometer Settings Fully Counter Clockwise
Max. Sensing Distance: Maximum Range Indicated On Photoelectric Switch Data-Sheets In 100 % Settings
Rated Insulation Voltage (UI): 250 VAC
Dielectric Voltage >2.0 KVAC (Rms)(Contacts / Electronics)
Rated Impulse Withstand Volt. 4 Kv (1.2/50 µs) (Contacts /Electronics) (IEC 664)
Operating Frequency (F)
- Light / Dark Ratio 1:1
- Relay Output 20 HZ
- Transistor Output 20 HZ
Response Time
- OFF-ON (Ton): 20 Ms
- ON-OFF (Toff): 30 Ms
Environment
- Overvoltage Category: III (IEC 60664)
- Degree Of Protection: IP 20 /IEC 60529, 60947-1)
- Pollution Degree: 3 (IEC 60664/60664A, 60947-1)
Temperature
- Operating: -20° To +50°c (-4° To +122°f)
- Storage: -50° To +85°c (-58° To +185°f)
Housing Material NORYL SE1, Light Grey
- AC Supply: 200 G
- AC/DC Supply: 125 G
Approvals: UL508, UL325*, CSA
CE Marking: EN12445, EN12453**,EN12978